YASKAWA III series SGM/SGDS Error A. E40: MECHATROLINK‑II Transmission Cycle Setting Fault

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Fault codeA. E40

This code indicates a transmission cycle setting error in MECHATROLINK-II communication occurred at the start of MECHATROLINK-II communication. The manual's first action is: “Zero‑speed stop”

Model
YASKAWA III series SGM/SGDS
Display shows
MECHATROLINK‑II Transmission Cycle Setting Fault (A. E40)
Type
Fault code
Source
Manual p. 291

What A. E40 means

MECHATROLINK‑II Transmission Cycle Setting Fault p. 291

Common causes

  • Transmission cycle setting error in MECHATROLINK‑II communication p. 291
  • Occurred at the start of MECHATROLINK‑II communication p. 291

What to do

  1. Zero‑speed stop p. 291
  2. MECHATROLINK‑II transmission cycle setting exceeds specification – set it to a correct value p. 291

Before you service the product, read the safety instructions in the manual p. 292.

If A. E40 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A. E40; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.