YASKAWA III series SGM/SGDS Error A. d10: Motor Load Position Deviation Too Large

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Error codeA. d10

This code indicates the motor load position deviation is too large, occurs when servo is ON or during operation. The manual's first action is: “Zero‑speed stop”

Model
YASKAWA III series SGM/SGDS
Display shows
Motor Load Position Deviation Too Large (A. d10)
Type
Error code
Source
Manual p. 291

What A. d10 means

Motor Load Position Deviation Too Large p. 291

Common causes

  • Motor load position deviation is too large p. 291
  • Occurs when servo is ON or during operation p. 291

What to do

  1. Zero‑speed stop p. 291
  2. Motor rotation direction and scale installation are opposite – reverse the scale installation direction or reverse the operating direction setting in “Closed‑Loop Encoder Usage (Pn002.3)” p. 291

Before you service the product, read the safety instructions in the manual p. 292.

If A. d10 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A. d10; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.