YASKAWA III series SGM/SGDS Error A. E60: MECHATROLINK‑II Communication Fault

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Fault codeA. E60

This code indicates continuous communication errors occur during MECHATROLINK-II communication or a servo unit fault. The manual's first action is: “Zero‑speed stop”

Model
YASKAWA III series SGM/SGDS
Display shows
MECHATROLINK‑II Communication Fault (A. E60)
Type
Fault code
Source
Manual p. 291

What A. E60 means

MECHATROLINK‑II Communication Fault p. 291

Common causes

  • Continuous communication errors occur during MECHATROLINK‑II communication p. 291
  • Occurs during MECHATROLINK‑II communication p. 291
  • Servo unit fault p. 291
  • MECHATROLINK‑II data reception error due to interference p. 291

What to do

  1. Zero‑speed stop p. 291
  2. MECHATROLINK‑II wiring is incorrect – correctly wire the communication cable and connect terminals properly p. 291
  3. Replace the servo unit p. 291
  4. Implement EMI mitigation (e.g., reinstall MECHATROLINK‑II cable, add ferrite cores on the cable and FG wiring) p. 291

Before you service the product, read the safety instructions in the manual p. 292.

If A. E60 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A. E60; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.