YASKAWA III series SGM/SGDS Error A. E51: MECHATROLINK‑II Synchronization Failure

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Fault codeA. E51

This code indicates a synchronization failure occurs during MECHATROLINK-II communication at the start of MECHATROLINK-II synchronized communication or a servo unit fault. The manual's first action is: “Zero‑speed stop”

Model
YASKAWA III series SGM/SGDS
Display shows
MECHATROLINK‑II Synchronization Failure (A. E51)
Type
Fault code
Source
Manual p. 291

What A. E51 means

MECHATROLINK‑II Synchronization Failure p. 291

Common causes

  • Synchronization failure occurs during MECHATROLINK‑II communication p. 291
  • Occurs at the start of MECHATROLINK‑II synchronized communication p. 291
  • Servo unit fault p. 291

What to do

  1. Zero‑speed stop p. 291
  2. At the start of synchronized communication, the command controller’s WDT data update is erroneous, preventing sync start – correctly update WDT data via the command controller p. 291
  3. Replace the servo unit p. 291

Before you service the product, read the safety instructions in the manual p. 292.

If A. E51 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A. E51; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.