This code indicates when servo is ON, accumulated position deviation exceeds user parameter, occurred when the control power was turned on, or when servo OFF, set so that the servo motor does not move. The manual's first action is: “DB stop”
- Model
- YASKAWA III series SGM/SGDS
- Display shows
- Servo‑ON Position Deviation Too Large Alarm (A. d01)
- Type
- Alarm code
- Source
- Manual p. 291
What A. d01 means
Servo‑ON Position Deviation Too Large Alarm p. 291
Common causes
- When servo is ON, accumulated position deviation exceeds user parameter (Pr526) p. 291
- Occurred when the control power was turned on p. 291
- When servo OFF, set so that the servo motor does not move p. 291
What to do
- DB stop p. 291
- When servo OFF, set so that the servo motor does not move p. 291
- Correctly set detection value p. 291
Before you service the product, read the safety instructions in the manual p. 292.
If A. d01 is still not resolved
- Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
- Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6 “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
This page summarises what the manufacturer’s manual says about A. d01; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.