YASKAWA III series SGM/SGDS Error A 810: Encoder backup alarm

YASKAWA III series SGM/SGDS servo unit · taken from the manufacturer’s manual, pages cited

Alarm codeA 810

Encoder backup alarm means the encoder power is completely depleted. The manual's first action is: “Position data is cleared”

Model
YASKAWA III series SGM/SGDS
Display shows
Encoder backup alarm (A 810)
Type
Alarm code
Source
Manual p. 290

What A 810 means

Encoder backup alarm p. 290

Common causes

  • Encoder power is completely depleted p. 290
  • Occurs when control power is turned on (parameter Pn002.2 = 1) p. 290
  • Occurs when control power is turned on (parameter Pn002.2 = 0) when used with an absolute encoder p. 290
  • Both the servo unit's PG power (+5 V) and battery power have failed p. 290
  • Absolute encoder fault p. 290

What to do

  1. Position data is cleared p. 290
  2. Replace the servo unit p. 290
  3. Perform encoder setup p. 290
  4. After restoring encoder power (e.g., replacing battery), perform encoder setup p. 290
  5. If the alarm does not clear after repeated setup attempts, replace the encoder p. 290

Before you service the product, read the safety instructions in the manual p. 292.

If A 810 is still not resolved

  • Unless designated personnel, do not perform settings, disassembly, and repair. Otherwise there is danger of electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”
  • Contact designated personnel for settings, disassembly, and repair to avoid electric shock or injury. p. 6
    “除非是指定的人员,否则不要进行设置、拆卸与修理。否则会有触电或导致受伤的危险。”

This page summarises what the manufacturer’s manual says about A 810; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.