Yaskawa FS100 Error 4072: MEMORY ERROR (LASER TRACKING TRACK START FILE)

Yaskawa FS100 · taken from the manufacturer’s manual, pages cited

Alarm code4072

The system detected an error in the laser tracking track start file memory. The manual's first action is: “(1)Reset the alarm. (2)If the alarm occurs again, initialize the laser tracking track start file in maintenance mode, and then load the laser tracking track start file saved in the external memory device.”

Model
Yaskawa FS100
Display shows
MEMORY ERROR (LASER TRACKING TRACK START FILE) (4072)
Type
Alarm code
Source
Manual p. 158

What 4072 means

MEMORY ERROR (LASER TRACKING TRACK START FILE) p. 158

Common causes

What to do

  1. (1)Reset the alarm. (2)If the alarm occurs again, initialize the laser tracking track start file in maintenance mode, and then load the laser tracking track start file saved in the external memory device. p. 158
  2. (1)Reset the alarm. (2)If the alarm occurs again, replace controller. Save the CMOS.BIN before replace controller to be safe. p. 158

If 4072 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.

This page summarises what the manufacturer’s manual says about 4072; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.