Yaskawa FS100 Error 4043: MEMORY ERROR (VISION CALIBRATION)

Yaskawa FS100 · taken from the manufacturer’s manual, pages cited

Alarm code4043

The system detected an error in the vision calibration memory data. The manual's first action is: “(1)Reset the alarm. (2)If the alarm occurs again, initialize the vision calibration file in maintenance mode, and then load the vision calibration file saved in the external memory device.”

Model
Yaskawa FS100
Display shows
MEMORY ERROR (VISION CALIBRATION) (4043)
Type
Alarm code
Source
Manual p. 157

What 4043 means

MEMORY ERROR (VISION CALIBRATION) p. 157

Common causes

What to do

  1. (1)Reset the alarm. (2)If the alarm occurs again, initialize the vision calibration file in maintenance mode, and then load the vision calibration file saved in the external memory device. p. 157
  2. (1)Reset the alarm. (2)If the alarm occurs again, replace controller. Save the CMOS.BIN before replace controller to be safe. p. 157

If 4043 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.

This page summarises what the manufacturer’s manual says about 4043; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.