MEMORY ERROR (ANTICIPATION OT FILE) indicates data or CPU board failure affecting anticipation output file storage. The manual's first action is: “(1)Reset the alarm. (2)If the alarm occurs again, initialize the anticipation output (OT) file in maintenance mode, and then load the anticipation output (OT) file saved in the external memory device.”
- Model
- Yaskawa FS100
- Display shows
- MEMORY ERROR (ANTICIPATION OT FILE) (4034)
- Type
- Alarm code
- Source
- Manual p. 156
What 4034 means
MEMORY ERROR (ANTICIPATION OT FILE) p. 156
Common causes
What to do
- (1)Reset the alarm. (2)If the alarm occurs again, initialize the anticipation output (OT) file in maintenance mode, and then load the anticipation output (OT) file saved in the external memory device. p. 156
- (1)Reset the alarm. (2)If the alarm occurs again, replace controller. Save the CMOS.BIN before replace controller to be safe. p. 156
If 4034 is still not resolved
- (1)Reset the alarm. (2)If the alarm occurs again, initialize the anticipation output (OT) file in maintenance mode, and then load the anticipation output (OT) file saved in the external memory device. p. 156 “(1)Reset the alarm. (2)If the alarm occurs again, initialize the anticipation output (OT) file in maintenance mode, and then load the anticipation output (OT) file saved in the external memory device.”
This page summarises what the manufacturer’s manual says about 4034; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.