Yaskawa FS100 Error 1102: SYSTEM ERROR (MAN-MACHINE APPLI)

Yaskawa FS100 · taken from the manufacturer’s manual, pages cited

Alarm code1102

A software operation error occurred in the man-machine application. The manual's first action is: “(1)Turn the power OFF then back ON. (2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure).”

Model
Yaskawa FS100
Display shows
SYSTEM ERROR (MAN-MACHINE APPLI) (1102)
Type
Alarm code
Source
Manual p. 131

What 1102 means

SYSTEM ERROR (MAN-MACHINE APPLI) p. 131

Common causes

  • Software operation error occurred p. 131

What to do

  1. (1)Turn the power OFF then back ON. (2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 131

If 1102 is still not resolved

  • (1)Turn the power OFF then back ON. (2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 131
    “(1)Turn the power OFF then back ON. (2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure).”

This page summarises what the manufacturer’s manual says about 1102; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.