Yaskawa FS100 Error 1105: SYSTEM ERROR (SERVO)

Yaskawa FS100 · taken from the manufacturer’s manual, pages cited

Alarm code1105

A system error has occurred in the servo control system. The manual's first action is: “(1)Turn the power OFF then back ON. (2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure).”

Model
Yaskawa FS100
Display shows
SYSTEM ERROR (SERVO) (1105)
Type
Alarm code
Source
Manual p. 131

What 1105 means

SYSTEM ERROR (SERVO) p. 131

Common causes

  • Software operation error occurred p. 131
  • Servo control board failure p. 131
  • A task request was sent to an axis in the alarm status. p. 131

What to do

  1. (1)Turn the power OFF then back ON. (2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 131
  2. (1)Turn the power OFF then back ON. (2)If the alarm occurs again, replace controller. Save the CMOS BIN before replace controller to be safe. p. 131

If 1105 is still not resolved

  • (1)Turn the power OFF then back ON. (2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure). p. 131
    “(1)Turn the power OFF then back ON. (2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and then contact your Yaskawa representative about occurrence status (operating procedure).”

This page summarises what the manufacturer’s manual says about 1105; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.