Toshiba VF-AS1 Error OCR: Dynamic braking element overcurrent (200V-55kW or larger, 400V-90kW or larger)

Toshiba VF-AS1 inverter · taken from the manufacturer’s manual, pages cited

Error codeOCR

The cooling fan does not rotate, the ambient temperature is too high, or the vent is blocked up. The manual's first action is: “Restart the operation by resetting the inverter after it has cooled down enough.”

Model
Toshiba VF-AS1
Display shows
OCR
Type
Error code
Source
Manual p. 295

What OCR means

Dynamic braking element overcurrent (200V-55kW or larger, 400V-90kW or larger) p. 295

Common causes

  • The cooling fan does not rotate. p. 295
  • The ambient temperature is too high. p. 295
  • The vent is blocked up. p. 295
  • A heat generating device is installed close to the inverter. p. 295
  • The thermistor in the unit is disconnected. p. 295

What to do

  1. Restart the operation by resetting the inverter after it has cooled down enough. p. 295
  2. The fan requires replacement if it does not rotate during operation. p. 295
  3. Secure sufficient space around the inverter. p. 295
  4. Do not place any heat generating device near the inverter. p. 295
  5. Make a service call. p. 295

Before you service the product, read the safety instructions in the manual p. 17.

If OCR is still not resolved

  • Read the Instruction Manual p. 17
    “Read the Instruction Manual.”

This page summarises what the manufacturer’s manual says about OCR; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Toshiba. Found a mistake? Report an error.