Fault codeL
The TMS7 has detected an incorrect motor FLC setting for a 3 Wire connection. The manual's first action is: “1. Reduce the motor FLC setting and then reset the TMS7. Note that this FLC cannot be reset until the FLC setting has been corrected. 2. Alternatively, remove control voltage from the”
- Model
- TMS7 ME00070B
- Display shows
- Out of range FLC (L)
- Type
- Fault code
- Source
- Manual p. 29
What L means
Out of range FLC p. 29
Common causes
- The TMS7 has detected that the motor is connected in the 3 Wire configuration and that Function 1. Motor FLC or Function 80 Motor FLC (secondary motor settings) has been set in excess of the TMS7's maximum capability for this connection format. p. 29
Safety warnings — read before you start
- CAUTIONCAUTION STATEMENTS. WARNING - ELECTRICAL SHOCK HAZARD The TMS7 contains dangerous voltages when connected to line voltage. Only a competent electrician should carry out the electrical installation. p. 3
What to do
- 1. Reduce the motor FLC setting and then reset the TMS7. Note that this FLC cannot be reset until the FLC setting has been corrected. 2. Alternatively, remove control voltage from the p. 29
If L is still not resolved
- Reduce the motor FLC setting and then reset the TMS7. p. 29 “1. Reduce the motor FLC setting and then reset the TMS7.”
This page summarises what the manufacturer’s manual says about L; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with TMS7. Found a mistake? Report an error.