Error code09

Code 09 indicates other auto-tuning errors excluding ATE-01 to ATE-08 errors such as no-load current exceeding 70%, rated current or torque exceeding reference 100%, or incorrect relationship between motor output current and motor rated current. The manual's first action is: “Check motor connection wires.”

Model
TECO A510
Display shows
Other auto‑tuning errors (09)
Type
Error code
Source
Manual p. 257

What 09 means

Other auto‑tuning errors p. 257

Common causes

  • Other auto‑tuning errors (excluding ATE‑01 to ATE‑08 errors, e.g., no‑load current >70 %, rated current or torque exceeds reference 100 %). p. 257
  • Incorrect relationship between motor output current and motor rated current. p. 257

What to do

  1. Check motor connection wires. p. 257
  2. Check auto‑tuning input data. p. 257
  3. Check auto‑tuning input data (22‑02). Check the inverter’s capacity. p. 257

Before you service the product, read the safety instructions in the manual p. 252.

If 09 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact TECO service.