TECO A510 Error 07: Deadtime compensation detection error

TECO A510 inverter · taken from the manufacturer’s manual, pages cited

Error code07

Code 07 indicates a deadtime compensation detection error due to other auto-tuning errors. The manual's first action is: “Increase acceleration time (00‑14).”

Model
TECO A510
Display shows
Deadtime compensation detection error (07)
Type
Error code
Source
Manual p. 257

What 07 means

Deadtime compensation detection error p. 257

Common causes

  • Other auto‑tuning errors. p. 257

What to do

  1. Increase acceleration time (00‑14). p. 257
  2. Disconnect the load connected to the motor. p. 257
  3. Check motor wiring. Check auto‑tuning input data. p. 257

Before you service the product, read the safety instructions in the manual p. 252.

If 07 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact TECO service.

This page summarises what the manufacturer’s manual says about 07; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with TECO. Found a mistake? Report an error.