TECO A510 Error USP: Unattended protection

TECO A510 inverter · taken from the manufacturer’s manual, pages cited

Warning codeUSP

USP on the TECO A510 is listed in the manual as: Unattended protection. The manual's first action is: “Close the run command, perform terminal reset action (set 03‑00 to 03‑07 to 3), or use the RESET key on the digital operator to reset.”

Model
TECO A510
Display shows
Unattended protection (USP)
Type
Warning code
Source
Manual p. 256

What USP means

Unattended protection p. 256

Common causes

  • When power‑on, unattended protection (as set in the multi‑function digital inputs) is enabled, and the inverter will not accept any run commands. p. 256
  • Until the warning message is cleared, the inverter cannot enter run mode. (See the full manual, sections 03‑00 to 03‑08=50, for details.) p. 256

What to do

  1. Close the run command, perform terminal reset action (set 03‑00 to 03‑07 to 3), or use the RESET key on the digital operator to reset. p. 256
  2. Turn off the USP signal and power‑cycle the unit. p. 256

Before you service the product, read the safety instructions in the manual p. 252.

If USP is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact TECO service.