TECO A510 Error 03: Motor leakage inductance calibration error.

TECO A510 inverter · taken from the manufacturer’s manual, pages cited

Fault code03

Code 03 indicates a motor leakage inductance calibration error when auto-tuning did not complete within the allotted time, auto-tuning result exceeds parameter settings, or exceeds motor rated current. The manual's first action is: “Check auto‑tuning input data (17‑00 to 17‑09).”

Model
TECO A510
Display shows
Motor leakage inductance calibration error. (03)
Type
Fault code
Source
Manual p. 257

What 03 means

Motor leakage inductance calibration error. p. 257

Common causes

  • Auto‑tuning did not complete within the allotted time. p. 257
  • Auto‑tuning result exceeds parameter settings. p. 257
  • Exceeds motor rated current. p. 257
  • Inverter three‑phase output is open. p. 257
  • System fault. p. 257

What to do

  1. Check auto‑tuning input data (17‑00 to 17‑09). p. 257
  2. Disconnect the load connected to the motor. p. 257
  3. Check the inverter’s current detection circuit, including the current sensor. p. 257
  4. Check motor connection wires. p. 257
  5. Check whether other protection routines have been entered. p. 257

Before you service the product, read the safety instructions in the manual p. 252.

If 03 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact TECO service.

This page summarises what the manufacturer’s manual says about 03; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with TECO. Found a mistake? Report an error.