TECO A510 Error 02: Motor line-to-line resistance R1 calibration error.

TECO A510 inverter · taken from the manufacturer’s manual, pages cited

Error code02

Code 02 indicates a motor line-to-line resistance R1 calibration error when there is no PG option card and cannot calibrate poles. The manual's first action is: “Check auto‑tuning input data (17‑00 to 17‑09).”

Model
TECO A510
Display shows
Motor line-to-line resistance R1 calibration error. (02)
Type
Error code
Source
Manual p. 257

What 02 means

Motor line-to-line resistance R1 calibration error. p. 257

Common causes

  • No PG option card; cannot calibrate poles. p. 257

What to do

  1. Check auto‑tuning input data (17‑00 to 17‑09). p. 257
  2. Check motor connection wires. p. 257
  3. Check that the PM PG card is installed correctly. p. 257

Before you service the product, read the safety instructions in the manual p. 252.

If 02 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact TECO service.

This page summarises what the manufacturer’s manual says about 02; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with TECO. Found a mistake? Report an error.