Fault codeF52984
Commissioning of the servo motor has failed. The incremental encoder motor is connected but fails to commission. The manual's first action is: “Configure the motor ID by setting the parameter p29000.”
- Model
- Siemens SINAMICS V90, SIMOTICS S-1FL6
- Display shows
- Incremental encoder motor not configured (F52984)
- Type
- Fault code
- Source
- Manual p. 303
What F52984 means
Incremental encoder motor not configured p. 303
Common causes
- Commissioning of the servo motor has failed. p. 303
- The incremental encoder motor is connected but fails to commission. p. 303
What to do
- Configure the motor ID by setting the parameter p29000. p. 303
Before you service the product, read the safety instructions in the manual p. 2.
If F52984 is still not resolved
- Contact service / dealer for assistance p. 2 “Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.”
- Contact service / dealer for assistance p. 13 “NOTICE Property damage due to loose power connections Insufficient tightening torques or vibration can result in loose power connections. This can result in damage due to fire, device defects or malfunctions.”
This page summarises what the manufacturer’s manual says about F52984; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.