The module booting was interrupted several times, causing it to reset to factory settings. The manual's first action is: “Carry out a POWER ON (power off/on). After switching on, the module reboots from the valid parameterization (if available).”
- Model
- Siemens SINAMICS V90, SIMOTICS S-1FL6
- Display shows
- Booting has been interrupted several times (F1018)
- Type
- Error code
- Source
- Manual p. 288
What F1018 means
Booting has been interrupted several times p. 288
Common causes
- Module booting was interrupted several times. As a consequence, the module boots with the factory setting. p. 288
- Possible reasons for booting being interrupted: p. 288
- After this fault is output, then the module is booted with the factory settings. p. 288
- Note: If the fault situation is repeated, then this fault is again output after several interrupted boots. p. 288
What to do
- Carry out a POWER ON (power off/on). After switching on, the module reboots from the valid parameterization (if available). p. 288
- Power supply interrupted. p. 288
- CPU crashed. p. 288
- Parameterization invalid. p. 288
- Restore the valid parameterization Examples: Carry out a first commissioning, save, carry out a POWER ON (switch-off/switch-on). p. 288
- Load another valid parameter backup (e.g. from the memory card), save, carry out a POWER ON (switch-off/switch-on). p. 288
Before you service the product, read the safety instructions in the manual p. 2.
If F1018 is still not resolved
- Contact service / dealer for assistance p. 2 “Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.”
- Contact service / dealer for assistance p. 13 “NOTICE Property damage due to loose power connections Insufficient tightening torques or vibration can result in loose power connections. This can result in damage due to fire, device defects or malfunctions.”
This page summarises what the manufacturer’s manual says about F1018; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.