Siemens SINAMICS V90, SIMOTICS S-1FL6 Error F1001: FloatingPoint exception

Industrial motor drive · taken from the manufacturer’s manual, pages cited

Fault codeF1001

A FloatingPoint exception occurred during an operation with floating-point data types. The manual's first action is: “Carry out a POWER ON (power off/on) for all components.”

Model
Siemens SINAMICS V90, SIMOTICS S-1FL6
Display shows
FloatingPoint exception (F1001)
Type
Fault code
Source
Manual p. 287

What F1001 means

FloatingPoint exception p. 287

Common causes

  • An exception occurred during an operation with the FloatingPoint data type. p. 287

Safety warnings — read before you start

  • DANGERGeneral Safety Instructions. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. p. 2
  • WARNINGRisk of Electric Shock and Fire. Risk of electric shock and fire from supply networks with an excessively low impedance Excessively high short-circuit currents can lead to the protective devices not being able to interrupt these short-circuit currents and being destroyed, and thus causing electric shock or a fire. p. 12
  • WARNINGElectric Shock if No Ground Connection. Electric shock if there is no ground connection For missing or incorrectly implemented protective conductor connection for devices with protection class I, high voltages can be present at open, exposed parts, which when touched, can result in death or severe injury. p. 12
  • WARNINGElectric Shock Due to Unsuitable Power Supply. Electric shock due to connection to an unsuitable power supply When equipment is connected to an unsuitable power supply, exposed components may carry a hazardous voltage that might result in serious injury or death. p. 12

What to do

  1. Carry out a POWER ON (power off/on) for all components. p. 287
  2. Upgrade firmware to the latest version. p. 287
  3. Contact the Hotline. p. 287

If F1001 is still not resolved

  • Contact service / dealer for assistance p. 2
    “Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.”
  • Contact service / dealer for assistance p. 13
    “NOTICE Property damage due to loose power connections Insufficient tightening torques or vibration can result in loose power connections. This can result in damage due to fire, device defects or malfunctions.”

This page summarises what the manufacturer’s manual says about F1001; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.