Error codeA0512
A0512 indicates Motor temperature signal lost when the signal wire to the motor temperature sensor is broken. The manual lists no action for this code.
- Model
- Siemens MICROMASTER 430
- Display shows
- Motor temperature signal lost (A0512)
- Type
- Error code
- Source
- Manual p. 88
What A0512 means
Motor temperature signal lost p. 88
Common causes
- Signal wire to the motor temperature sensor is broken. If a broken signal wire is detected, the temperature‑monitoring switch should be switched to use the motor temperature model for monitoring. p. 88
If A0512 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.
This page summarises what the manufacturer’s manual says about A0512; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.