Fault codeF06310
The measured DC voltage is outside the tolerance range after precharging, requiring drive shutdown to acknowledge the fault. The manual lists no action for this code.
- Model
- Siemens G120C
- Display shows
- Supply voltage (p0210) incorrectly parameterized (F06310)
- Type
- Fault code
- Source
- Manual p. 697
What F06310 means
Supply voltage (p0210) incorrectly parameterized p. 697
Common causes
- The measured DC voltage lies outside the tolerance range after precharging has been completed. p. 697
- Permissible range: 1.16 * p0210 < r0070 < 1.6 * p0210 p. 697
- Note: The fault can only be acknowledged when the drive is switched off. p. 697
- See also: p0210 (Drive unit line supply voltage) p. 697
If F06310 is still not resolved
This page summarises what the manufacturer’s manual says about F06310; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.