Fault codeF07016
An error was detected when evaluating the temperature sensor set in p0601, indicating wire breakage or sensor not connected. The manual lists no action for this code.
- Model
- Siemens CU240B/E-2
- Display shows
- Drive: Motor temperature sensor fault (F07016)
- Type
- Fault code
- Source
- Manual p. 691
What F07016 means
Drive: Motor temperature sensor fault p. 691
Common causes
- An error was detected when evaluating the temperature sensor set in p0601. p. 691
- - wire breakage or sensor not connected (KTY: R > 2120 Ohm). p. 691
- - measured resistance too low (PTC: R < 20 Ohm, KTY: R < 50 Ohm). p. 691
If F07016 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.
This page summarises what the manufacturer’s manual says about F07016; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.