Fault codeUPI
Input voltage is too low. The manual's first action is: “• Check the input voltage and correct the fault.”
- Model
- Schneider Electric ATV212
- Display shows
- [Undervoltage] (UPI)
- Type
- Fault code
- Source
- Manual p. 155
What UPI means
[Undervoltage] p. 155
Common causes
- • Input voltage is too low. p. 155
What to do
- • Check the input voltage and correct the fault. p. 155
- • Select the correct setting for parameter F627. p. 155
- • Activate the load‑tracking function F301. p. 155
- • Set parameter F302 to 2. p. 155
Before you service the product, read the safety instructions in the manual p. 5.
If UPI is still not resolved
- 与当地的 Schneider Electric 代表联系 p. 7 “如果直流总线电容未完全放电,请与当地的 Schneider Electric 代表联系”
This page summarises what the manufacturer’s manual says about UPI; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.