Schneider Electric ATV212 Error UPI: [Undervoltage]

Schneider Electric ATV212 · taken from the manufacturer’s manual, pages cited

Fault codeUPI

Input voltage is too low. The manual's first action is: “• Check the input voltage and correct the fault.”

Model
Schneider Electric ATV212
Display shows
[Undervoltage] (UPI)
Type
Fault code
Source
Manual p. 155

What UPI means

[Undervoltage] p. 155

Common causes

  • • Input voltage is too low. p. 155

What to do

  1. • Check the input voltage and correct the fault. p. 155
  2. • Select the correct setting for parameter F627. p. 155
  3. • Activate the load‑tracking function F301. p. 155
  4. • Set parameter F302 to 2. p. 155

Before you service the product, read the safety instructions in the manual p. 5.

If UPI is still not resolved

  • 与当地的 Schneider Electric 代表联系 p. 7
    “如果直流总线电容未完全放电,请与当地的 Schneider Electric 代表联系”

This page summarises what the manufacturer’s manual says about UPI; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.