Fault codeSOF
SOF on the Schneider Altivar 12 is listed in the manual as: Overspeed. The manual's first action is: “Check the motor”
- Model
- Schneider Altivar 12
- Display shows
- Overspeed (SOF)
- Type
- Fault code
- Source
- Manual p. 108
What SOF means
Overspeed p. 108
Common causes
What to do
- Check the motor p. 108
- Overspeed is 10% more than Maximum frequency bFr page 57 so adjust this parameter if necessary p. 108
- Add a braking resistor p. 108
- Check the size of the motor/drive/load p. 108
- Check parameters of the speed loop (gain and stability) p. 108
Before you service the product, read the safety instructions in the manual p. 4.
If SOF is still not resolved
- contact your local Schneider Electric representative p. 5 “contact your local Schneider Electric representative. Do not repair or operate the drive.”
This page summarises what the manufacturer’s manual says about SOF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider. Found a mistake? Report an error.