Schneider Altivar 12 Error OBF: Overbraking

Altivar 12 variable speed drive · taken from the manufacturer’s manual, pages cited

Fault codeOBF

OBF on the Schneider Altivar 12 is listed in the manual as: Overbraking. The manual's first action is: “• Increase the deceleration time • Install a module unit with a braking resistor if necessary • Check the line supply voltage, to be sure that it is under the maximum acceptable (20% over maximum line supply during run status)”

Model
Schneider Altivar 12
Display shows
Overbraking (OBF)
Type
Fault code
Source
Manual p. 109

What OBF means

Overbraking p. 109

Common causes

  • • Braking too sudden or driving load too high p. 109

What to do

  1. • Increase the deceleration time • Install a module unit with a braking resistor if necessary • Check the line supply voltage, to be sure that it is under the maximum acceptable (20% over maximum line supply during run status) p. 109

Before you service the product, read the safety instructions in the manual p. 4.

If OBF is still not resolved

  • contact your local Schneider Electric representative p. 5
    “contact your local Schneider Electric representative. Do not repair or operate the drive.”

This page summarises what the manufacturer’s manual says about OBF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider. Found a mistake? Report an error.