IC ERROR happens due to aberration in the communication integrated circuit or noise affecting the RS485 cable. The manual's first action is: “Replace the MULTI CONTROLLER.”
- Model
- Sanyo Machine Works SDNR
- Display shows
- IC ERROR (EC)
- Type
- Error code
- Source
- Manual p. 109
What EC means
IC ERROR p. 144
Common causes
- The aberration of the communication integrated circuit. p. 144
- The aberration of the RS485 cable by noise etc. p. 144
What to do
- Replace the MULTI CONTROLLER. p. 144
- Check the connection of the RS485 cables. Replace the cable if the trouble occurs after confirming the connection. p. 144
- Inform us about the environment (power noise or another noise source, etc) around the NUTRUNNER system. p. 144
Before you service the product, read the safety instructions in the manual p. 65.
If EC is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Sanyo Machine Works service.
This page summarises what the manufacturer’s manual says about EC; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Sanyo Machine Works. Found a mistake? Report an error.