DOUBLE ID ERROR occurs when the DIP switch (DSW1) is wrong, multiple DISPLAY PANELS are connected, or the RS485 cable or its connection is wrong. The manual's first action is: “Correct the setting of the DRIVER's DIP switch (DSW1).”
- Model
- Sanyo Machine Works SDNR
- Display shows
- DOUBLE ID ERROR (EB)
- Type
- Error code
- Source
- Manual p. 109
What EB means
DOUBLE ID ERROR p. 144
Common causes
- DIP switch (DSW1) is wrong. The DRIVER of the same spindle No. exists. p. 144
- Two or more DISPLAY PANELS are connected. p. 144
- RS485 cable or its connection is wrong. p. 144
- The aberration of the RS485 cable by noise, etc. p. 144
What to do
- Correct the setting of the DRIVER's DIP switch (DSW1). p. 144
- Check the connection of the DISPLAY PANEL. p. 144
- Check the connection of the RS485 cable. Replace the cable if the trouble occurs after confirming the connection. p. 144
- Inform us about the environment around the NUTRUNNER (power noise or another noise source, etc.). p. 144
Before you service the product, read the safety instructions in the manual p. 65.
If EB is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Sanyo Machine Works service.
This page summarises what the manufacturer’s manual says about EB; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Sanyo Machine Works. Found a mistake? Report an error.