RECONFIGURATION ERROR occurs when power was interrupted or RS485 cables are damaged due to noise or improper connection. The manual's first action is: “Check the power source of DRIVER and DISPLAY PANEL.”
- Model
- Sanyo Machine Works SDNR
- Display shows
- RECONFIGURATION ERROR (EA)
- Type
- Error code
- Source
- Manual p. 109
What EA means
RECONFIGURATION ERROR p. 143
Common causes
- The power to the DISPLAY PANEL or DRIVER was interrupted. p. 143
- RS485 cable or its connection is wrong. p. 143
- The aberration of the RS485 cable by noise etc. p. 143
What to do
- Check the power source of DRIVER and DISPLAY PANEL. p. 143
- Check the connection of the RS485 cable. Replace the cable if the trouble still occurs. p. 143
- Inform us about the environment around the NUTRUNNER (power noise or another noise source, etc.). p. 143
Before you service the product, read the safety instructions in the manual p. 65.
If EA is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Sanyo Machine Works service.
This page summarises what the manufacturer’s manual says about EA; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Sanyo Machine Works. Found a mistake? Report an error.