Panasonic Minas A4 Error 38: Travel Limit Switch Inhibit Input Signal Error

Panasonic Minas A4 AC Servo Driver · taken from the manufacturer’s manual, pages cited

Error code38

The Travel Limit Switch Inhibit Input Signal Error code indicates the CW and CCW travel inhibit input terminals are both open-circuit to the COM-terminal when parameter Pr04 is set to 0. The manual's first action is: “Inspect the limit switches, their cables, and the power to the CW and CCW limit switches. Pay particular attention to the DC control signal supply (12–24 V) and ensure there is no delay when the signal is ON.”

Model
Panasonic Minas A4
Display shows
Travel Limit Switch Inhibit Input Signal Error (38)
Type
Error code
Source
Manual p. 65

What 38 means

Travel Limit Switch Inhibit Input Signal Error p. 65

Common causes

  • When parameter Pr04 (Travel limit inhibit input invalid) is set to 0, the CW and CCW travel inhibit input terminals (CWL: X5 pin 8, CCWL: X5 pin 9) are both open‑circuit to the COM‑ terminal. If Pr04 is set to 2, either CWL or CCWL is open‑circuit to COM‑. p. 65

What to do

  1. Inspect the limit switches, their cables, and the power to the CW and CCW limit switches. Pay particular attention to the DC control signal supply (12–24 V) and ensure there is no delay when the signal is ON. p. 65

Before you service the product, read the safety instructions in the manual p. 72.

If 38 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Panasonic service.

This page summarises what the manufacturer’s manual says about 38; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Panasonic. Found a mistake? Report an error.