Panasonic Minas A4 Error 40: Absolute Encoder System Power Loss

Panasonic Minas A4 AC Servo Driver · taken from the manufacturer’s manual, pages cited

Alarm code40

The Absolute Encoder System Power Loss code indicates the absolute encoder power supply has been lost. The manual's first action is: “Reconnect the battery and clear the absolute encoder data. The alarm can only be cleared after the data is cleared.”

Model
Panasonic Minas A4
Display shows
Absolute Encoder System Power Loss (40)
Type
Alarm code
Source
Manual p. 65

What 40 means

Absolute Encoder System Power Loss p. 65

Common causes

  • The absolute encoder power supply has been lost. p. 65

What to do

  1. Reconnect the battery and clear the absolute encoder data. The alarm can only be cleared after the data is cleared. p. 65

Before you service the product, read the safety instructions in the manual p. 72.

If 40 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Panasonic service.

This page summarises what the manufacturer’s manual says about 40; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Panasonic. Found a mistake? Report an error.