The Deviation Counter Overflow code indicates the position deviation counter value exceeds 2^27 (134,217,728). The manual's first action is: “Periodically inspect the external feedback device wiring and correct any wiring errors.”
- Model
- Panasonic Minas A4
- Display shows
- Deviation Counter Overflow (29)
- Type
- Error code
- Source
- Manual p. 64
What 29 means
Deviation Counter Overflow p. 64
Common causes
- The position deviation counter value exceeds 2^27 (134,217,728). p. 64
What to do
- Periodically inspect the external feedback device wiring and correct any wiring errors. p. 64
Before you service the product, read the safety instructions in the manual p. 72.
If 29 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Panasonic service.
This page summarises what the manufacturer’s manual says about 29; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Panasonic. Found a mistake? Report an error.