The Absolute Encoder Overspeed code indicates when powered only by the battery, the encoder speed exceeds the specified limit. The manual's first action is: “Check the encoder side supply voltage (DC5V ±5%). Verify that connector X5 wiring is correct. The alarm can only be cleared after the data is cleared.”
- Model
- Panasonic Minas A4
- Display shows
- Absolute Encoder Overspeed (42)
- Type
- Alarm code
- Source
- Manual p. 65
What 42 means
Absolute Encoder Overspeed p. 65
Common causes
- When powered only by the battery, the encoder speed exceeds the specified limit. p. 65
What to do
- Check the encoder side supply voltage (DC5V ±5%). Verify that connector X5 wiring is correct. The alarm can only be cleared after the data is cleared. p. 65
Before you service the product, read the safety instructions in the manual p. 72.
If 42 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Panasonic service.
This page summarises what the manufacturer’s manual says about 42; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Panasonic. Found a mistake? Report an error.