Error code27

The Command Pulse Division Error code indicates parameters Pr48–Pr4B are set incorrectly. The manual's first action is: “Ensure the external feedback device’s supply voltage is DC5V ±5% (4.75–5.25 V), especially when using a long feedback device. If the motor cable and the external feedback device’s wiring are bundled together, separate them. According to the wiring diagram, connect the shield wire to FG.”

Model
Panasonic Minas A4
Display shows
Command Pulse Division Error (27)
Type
Error code
Source
Manual p. 64

What 27 means

Command Pulse Division Error p. 64

Common causes

  • Parameters Pr48–Pr4B (the numerator and denominator of the electronic gear’s first and second stages) are set incorrectly. p. 64

What to do

  1. Ensure the external feedback device’s supply voltage is DC5V ±5% (4.75–5.25 V), especially when using a long feedback device. If the motor cable and the external feedback device’s wiring are bundled together, separate them. According to the wiring diagram, connect the shield wire to FG. p. 64

Before you service the product, read the safety instructions in the manual p. 72.

If 27 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Panasonic service.

This page summarises what the manufacturer’s manual says about 27; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Panasonic. Found a mistake? Report an error.