Panasonic Minas A4 Error 24: Position Deviation Too Large

Panasonic Minas A4 AC Servo Driver · taken from the manufacturer’s manual, pages cited

Error code24

The Position Deviation Too Large code indicates the value of the position deviation pulse counter exceeds the setting of parameter Pr70. The manual's first action is: “1) Ensure the motor runs correctly according to the command pulses. Monitor the torque monitor to ensure output torque is not saturated. Adjust the gain. Set Pr5E and Pr5F to their maximum values. According to the wiring diagram, connect the encoder wiring correctly.”

Model
Panasonic Minas A4
Display shows
Position Deviation Too Large (24)
Type
Error code
Source
Manual p. 64

What 24 means

Position Deviation Too Large p. 64

Common causes

  • The value of the position deviation pulse counter exceeds the setting of parameter Pr70 (position deviation limit). 1) The motor is not operating correctly according to the command pulses. p. 64
  • 2) The Pr70 value is set too low. p. 64

What to do

  1. 1) Ensure the motor runs correctly according to the command pulses. Monitor the torque monitor to ensure output torque is not saturated. Adjust the gain. Set Pr5E and Pr5F to their maximum values. According to the wiring diagram, connect the encoder wiring correctly. p. 64
  2. 2) Increase the Pr70 value. p. 64

Before you service the product, read the safety instructions in the manual p. 72.

If 24 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Panasonic service.

This page summarises what the manufacturer’s manual says about 24; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Panasonic. Found a mistake? Report an error.