Panasonic Minas A4 Error 25: Hybrid Control Position Deviation Too Large

Panasonic Minas A4 AC Servo Driver · taken from the manufacturer’s manual, pages cited

Error code25

The Hybrid Control Position Deviation Too Large code indicates the load position detected by the external feedback device does not match the motor position detected by the encoder. The manual's first action is: “Avoid excessively high command speeds. Check the command pulse frequency and division ratio. For overshoot caused by inappropriate gain, adjust the gain correctly. According to the wiring diagram, connect the encoder wiring correctly.”

Model
Panasonic Minas A4
Display shows
Hybrid Control Position Deviation Too Large (25)
Type
Error code
Source
Manual p. 64

What 25 means

Hybrid Control Position Deviation Too Large p. 64

Common causes

  • The load position detected by the external feedback device does not match the motor position detected by the encoder, exceeding the setting of parameter Pr7B (hybrid control deviation limit). p. 64

What to do

  1. Avoid excessively high command speeds. Check the command pulse frequency and division ratio. For overshoot caused by inappropriate gain, adjust the gain correctly. According to the wiring diagram, connect the encoder wiring correctly. p. 64

Before you service the product, read the safety instructions in the manual p. 72.

If 25 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Panasonic service.

This page summarises what the manufacturer’s manual says about 25; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Panasonic. Found a mistake? Report an error.