Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
For AC/AC drive units, the measured DC voltage after pre-charging is outside the tolerance range due to incorrectly parameterized supply voltage. The manual's first action is: “• Check the parameterized supply voltage…
The inverter heat sink has exceeded its over-temperature alarm threshold. The manual's first action is: “Check the following: • Is the surrounding temperature within the defined limit values? • Have the load condition…
The drive cannot synchronize with the master sign-of-life because the bus is in data exchange state and clock synchronous operation was selected using the parameterizing telegram. The manual's first action is: “Ensure…
The bus is in the data exchange state and clock synchronous operation has been selected using the parameterizing telegram. It was not possible to synchronize to the clock cycle specified by the master. The manual's fi…
There is no clock synchronization or clock synchronous sign of life and DSC is selected. The manual's first action is: “Set clock synchronization across the bus configuration and transfer clock synchronous sign-of-life.”
Output data of Drive Bus master (set-points) received at the incorrect instant in time within the Drive Bus clock cycle. The manual's first action is: “Check bus configuration.”
Parameterization for isochronous operation is not permissible. The manual's first action is: “Adapt the bus parameterization Tdp, Ti, To.”
An error was detected when evaluating the parameter files saved in the non-volatile memory. The manual's first action is: “Save the parameterization using the "Copy RAM to ROM" function on the BOP. This overwrites the…
The parameters of an individual drive object were saved, although there is still no backup of all drive system parameters. The manual's first action is: “Save all parameters.”
The write access to the removable data medium was unsuccessful. The manual's first action is: “Remove and check the removable data medium. Then run the data backup again.”
The temperature of the control module (Control Unit) has exceeded the specified limit value. The manual's first action is: “Check the air intake for the Control Unit. Check the Control Unit fan.”
Incorrect absolute encoder data. The manual's first action is: “Contact the Hotline.”
Motor ID is downloaded wrong during manufacture. The firmware of the servo drive does not support the Motor ID. The manual's first action is: “Update the firmware.”
Commissioning of the servo motor has failed. The incremental encoder motor is connected but fails to commission. The manual's first action is: “Configure the motor ID by setting the parameter p29000.”
The servo drive in use does not support encoderless operation. The manual's first action is: “Check the encoder cable connection between the servo drive and the servo motor.”