Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Motor overtemperature due to overload, high ambient temperature, or sensor disconnection. The manual's first action is: “Reduce the motor load.”
Exceeded the maximum allowable errors in controller sign-of-life during cyclic operation on PROFIdrive. The manual's first action is: “• Physically check the bus (cables, connectors, terminating resistor, shielding, e…
The global clock synchronization signal failed, violating time grid specifications in DP communication. The manual's first action is: “• Check the physical bus configuration (cable, connector, terminating resistor, sh…
Setpoints from the fieldbus interface (Modbus/USS) were not received due to communication interruption. The manual's first action is: “Restore the bus connection and set the controller to RUN.”
The drive's Safety Integrated (SI) function detected a defect and initiated an STO safety stop. The manual's first action is: “• Make sure that the high level duration of the input pulse is larger than 500 ms.”
For active PC master control, no sign-of-life signal was received within the monitoring time period. The manual's first action is: “Contact the Hotline.”
The module booting was interrupted several times, causing it to reset to factory settings. The manual's first action is: “Carry out a POWER ON (power off/on). After switching on, the module reboots from the valid para…
An internal software error has occurred on the Siemens SINAMICS V90, SIMOTICS S-1FL6 drive system. The manual's first action is: “Carry out a POWER ON (power off/on) for all components.”
A memory area was accessed that does not return a "READY" signal. The manual's first action is: “Carry out a POWER ON (power off/on).”
An internal software error has occurred. The manual's first action is: “Carry out a POWER ON (power off/on) for all components.”
A FloatingPoint exception occurred during an operation with floating-point data types. The manual's first action is: “Carry out a POWER ON (power off/on) for all components.”
An internal software error has occurred. The manual's first action is: “Evaluate fault buffer.”
This is the first fault in a case of multiple faults. The manual's first action is: “Slow flashing in red”
The line filter monitoring detected an excessively high temperature or another impermissible state. The manual's first action is: “Check the temperature/temperature monitoring. Check the configuration to ensure that i…
The braking controller or Braking Module is faulted or overloaded due to temperature issues. The manual's first action is: “Check the connection/state of the Braking Module. Comply with the permissible number of braki…