In a traversing block, the target position exceeds the software limit switch plus range requiring correction of the block programming. The manual's first action is: “Correct the traversing block.”
The target position in a traversing block exceeds the software limit switch minus range and requires adjustment of that limit. The manual's first action is: “Correct the traversing block.”
In a traversing block, a jump command was programmed to a non-existent block number requiring addition of the missing block. The manual's first action is: “Correct the traversing block.”
The task parameter in the traversing block contains an illegal value that violates system constraints. The manual's first action is: “Correct the task parameter in the traversing block.”
For a traversing block with CONTINUE_EXTERNAL_ALARM enabled, an external block change signal (STW1.13) is missing and not being triggered. The manual's first action is: “Resolve the reason as to why the edge is missin…
The selected traversing block exceeds the block number limit or was suppressed due to invalid programming in PROFINET control words. The manual's first action is: “Correct the traversing program.”
No reference point is set when starting a traversing block or direct setpoint input, causing this alarm to trigger. The manual's first action is: “Reference the system (search for reference, flying referencing, set re…
An illegal combination of input signals that are simultaneously active has been detected in EPOS operation. The manual's first action is: “Check the appropriate input signals and correct.”
The actual setpoint velocity exceeds the parameterized maximum velocity limit and has been internally restricted. The manual's first action is: “Check the entered setpoint velocity.”
The maximum velocity parameter is too high, preventing correct modulo correction calculation for EPOS operation. The manual's first action is: “Reduce the maximum velocity (p2571).”
Position value preprocessing is unable to validate an assigned encoder because no valid encoder data set exists or is improperly assigned. The manual's first action is: “Check the drive data sets, encoder data sets an…
The absolute encoder adjustment offset has been saved, triggering this alarm as a status change notification. The manual's first action is: “Not necessary. This alarm automatically disappears after the offset has been…
The calculated jerk time exceeds the internal limit of 1000 ms due to excessively high acceleration or deceleration settings. The manual's first action is: “• Increase the jerk limiting (p2574). • Reduce maximum accel…
The moment of inertia estimator has not yet stabilized and is unable to provide valid values for the drive's operation. The manual's first action is: “Traverse the axis until the moment of inertia estimator has stabil…
The motor temperature model 1/3 has detected that its alarm threshold has been exceeded. The manual's first action is: “• Check the motor load and reduce it if required. • Check the motor surrounding temperature.”