Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Hi error code is active, indicating process variable is above the maximum scale limit as set by parameter Hi S in the inP rEnU. The manual lists no action for this code.
Lo error code is active, indicating process variable is below the minimum scale limit as set by parameter LoS in the inP rEnU. The manual lists no action for this code.
No error has occurred. The manual lists no action for this code.
Third wire for PT100, PTC, or input values below minimum limits due to wrong connection. The manual lists no action for this code.
The probe is broken or input values exceed the maximum allowed limits. The manual lists no action for this code.
Process variable is above the maximum scale limit as set by parameter Hi S in the inP rEnU. The manual lists no action for this code.
Process variable is below the minimum scale limit as set by parameter LoS in the inP rEnU. The manual lists no action for this code.
All 9 error codes of the Gefran 1200/1300 temperature controller with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
Electrical Grounding error occurs when there is an electrical short detected in any component of the system. The manual lists no action for this code.
Venturi Blockage means the Venturi is physically blocked and technical support should be contacted for assistance. The manual lists no action for this code.
Venturi Control error occurs when Venturi motor isn't operating correctly, gas valve assembly needs replacement, or diagnostic code requires power reset. The manual lists no action for this code.
Heat Exchanger Overheat means heat exchanger switch resistance is measured and abnormal, or there are hot spots indicating scale build-up requiring flushing or hard water treatment. The manual lists no action for this…
No Flame error occurs when gas supply is off at the water heater, gas meter, or cylinder, propane tank is empty, or flame rod wire is disconnected. The manual lists no action for this code.
Air Supply or Exhaust Blockage/Condensate Trap is Full indicates condensate line is blocked, internal air filter is obstructed, or high altitude setting is not properly configured. The manual lists no action for this …
By-Pass Flow Control error occurs when resistance values of the by-pass flow control are measured and abnormal. The manual's first action is: “Replace By-Pass flow control device.”