Processor 2’s Safety Integrated function detected an error in the safety data sign-of-life and initiated a STOP A. The manual's first action is: “OFF2”
Processor 2 detected a monitoring channel defect, causing it to trigger STOP A and resulting in fault F30600. The manual's first action is: “As a consequence of this fault, fault F30600 (SI P2: STOP A initiated) is ou…
Processor 2’s Safety Integrated function initiated a STOP A due to an error during safety shutdown path checking or response to fault F30611. The manual lists no action for this code.
The power unit detected overvoltage in the DC link due to excessive voltage or incorrectly sized line reactor. The manual lists no action for this code.
At least one actual value channel on the Power Stack Adapter detected an error in its readings. The manual lists no action for this code.
The power unit performed too many switching operations due to current limitation or incorrect parameterization or motor fault. The manual lists no action for this code.
The fan in the power unit has operated for more than 500 hours, exceeding its maximum allowed operating time. The manual's first action is: “This message indicates the following: Fault value (0949, decimal interpretat…
The power unit failed to pre-charge the DC link within the expected time frame. The manual's first action is: “OFF2”
The power unit has detected chip overtemperature because the permissible load duty cycle was not maintained. The manual's first action is: “Acknowledge: IMMEDIATELY”
The power unit has detected overtemperature due to exceeding the permissible load duty cycle. The manual's first action is: “Acknowledge: IMMEDIATELY”
The monitoring of the collector-emitter voltage (U_ce) of the semiconductor in the power unit has responded. The manual's first action is: “Acknowledge: POWER ON”
The power unit has detected a ground fault. The manual's first action is: “OFF2”
The hardware current limitation in the relevant phase has responded too often. The manual's first action is: “OFF2”
A fault occurred during the vibration test for speed controller optimization. The manual's first action is: “- check the motor parameters (rating plate data). After the change: Calculate p0340 = 3.”
A fault occurred while identifying the moment of inertia during speed controller optimization. The manual's first action is: “- check the motor parameters (rating plate data). After the change: Calculate p0340 = 3.”