The macro cannot be executed due to an error. The manual lists no action for this code.
The closed-loop control parameters have been parameterized incorrectly. The manual lists no action for this code.
An error was detected when evaluating the temperature sensor set in p0601, indicating wire breakage or sensor not connected. The manual lists no action for this code.
An error was detected when evaluating the temperature sensor set in p0601, and a timer is started if the fault persists. The manual lists no action for this code.
The thermal I2t motor model identified that the temperature alarm threshold was exceeded. The manual lists no action for this code.
The motor temperature has exceeded the fault threshold or timer after the alarm threshold was exceeded. The manual lists no action for this code.
Phase failure of a braking resistor has been detected. The manual lists no action for this code.
At least one calibration data point for the analog inputs was determined to be invalid during booting. The manual's first action is: “- power down/power up the power supply for the Control Unit. If it reoccurs, replac…
The input current of the analog input has undershot the threshold value parameterized in p0761[...3]. The manual's first action is: “Check the connection to the signal source for interruptions. Check the magnitude of …
When accessing the Safety Integrated parameters for the processor 2 in non-volatile memory, an error occurred. The manual's first action is: “- re-commission the safety functions.”
An error occurred when aligning the Safety Integrated monitoring functions on processor 1 and processor 2, as no common set of supported SI monitoring functions was determined. The manual's first action is: “- carry o…
There is a PROFIBUS configuration error for using Safety Integrated monitoring functions with a higher-level control. The manual's first action is: “check and, if necessary, correct the PROFIBUS configuration of the s…
The "Safety Integrated" function requires synchronization of the safety time slices between processor 1 and processor 2, but this was unsuccessful. The manual's first action is: “OFF2”
The drive-integrated "Safety Integrated" function on processor 1 requires an acceptance test. The manual's first action is: “OFF2”
The drive-integrated "Safety Integrated" function on processor 1 has detected an error and initiated a STOP A. The manual's first action is: “OFF2”