Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Follower fault occurs when one or more follower drives trip to fault while using normal Master Follower function. The manual lists no action for this code.
Over Temp. occurs when temperature exceeds set limit due to sensor disconnection or short circuit, requiring investigation of temperature rise cause. The manual's first action is: “Find the cause of temperature rise.”
Input switch open error indicates the drive’s main power switch is open. The manual's first action is: “Do a check of the main power switch of the drive.”
Emergency stop is triggered by an emergency stop command received from digital input or fieldbus, and a new run command can be accepted after reset. The manual's first action is: “New run command is accepted after res…
Counter fault occurs when displayed counter values are incorrect. The manual lists no action for this code.
EEPROM checksum fault indicates a parameter save failure or operation malfunction with defective components, requiring distributor contact if recurring. The manual's first action is: “If the fault occurs again, ask in…
Unbalance fault occurs due to power module imbalance in parallel-connected units. The manual's first action is: “If the fault occurs again, ask instructions from the distributor near to you.”
Motor underload protection trips when the motor is not receiving sufficient load. The manual's first action is: “Do a check of the load.”
Motor overtemperature happens when excessive load causes motor overheating, requiring load reduction or parameter check. The manual's first action is: “Decrease the motor load. If there is no motor overload, do a chec…
Motor stalled fault occurs when the motor has stopped due to mechanical load or obstruction. The manual's first action is: “Do a check of the motor and the load.”
Frequency converter overtemperature is triggered if the heatsink exceeds 90 °C (194 °F) or 85 °C (185 °F), depending on model, requiring cooling and ambient checks. The manual's first action is: “Do a check of the act…
Frequency converter undertemperature occurs when the heatsink temperature drops below -10 °C (14 °F). The manual lists no action for this code.
Brake chopper supervision error happens if there is no brake resistor, a broken resistor, or defective brake chopper. The manual's first action is: “Do a check of the brake resistor and the cabling. If they are in goo…
Output phase supervision fault occurs when current measurement shows no current in one motor phase, indicating possible motor or cable issues. The manual's first action is: “Do a check of the motor cable and the motor.”
Input line supervision error indicates a missing phase in the input line supply, requiring check of voltage, fuses, and cable. The manual's first action is: “Do a check of the supply voltage, the fuses and supply cable.”