Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
PV input exceeds +10% of the range (Over-range). The manual's first action is: “Check the sensor and wiring. Check the PV range.”
All 8 error codes of the Yamatake SDC20/21 digital indicating controller with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
Room temperature sensor for heating circuit 1 is unavailable, which may be normal operation without room influence. The manual's first action is: “Check external room temperature sensor in heating circuit or room temp…
Emergency function is activated for heating circuit 2 due to short circuit in the flow temperature sensor with mixer. The manual's first action is: “Check flow temperature sensor, mixer 2. Measure voltage at sensor in…
Emergency function is activated for heating circuit 2 due to lead break, flow temperature sensor, or incorrect setting during commissioning. The manual's first action is: “Check flow temperature sensor, mixer 2. Measu…
The burner is in a fault state because of condensate backup in the heat cell. The manual's first action is: “Check system for condensate backup. Check the condensate drain and trap. Replace insulation blocks, electrod…
The burner is in a fault state due to a lead break or flow temperature sensor/high limit safety cut-out issue. The manual's first action is: “Check the flow temperature sensor/high limit safety cut-out. Replace faulty…
Fault 184 means the burner is in a fault state because of a short circuit in the flow temperature sensor or high limit safety cut-out. The manual's first action is: “Check the flow temperature sensor/high limit safety…
Fault 183 indicates no DHW heating due to a lead break in the outlet temperature sensor (if installed). The manual's first action is: “Check outlet temperature sensor (plug X7, cores 3 and 4).”
Fault 182 means no DHW heating because there is a short circuit in the outlet temperature sensor (if installed). The manual's first action is: “Check outlet temperature sensor (plug X7, cores 3 and 4). Measure sensor …
Fault 163 indicates the burner is in a fault state due to a checksum error during data memory access on the HBMU heat management unit. The manual's first action is: “Reset the appliance. If the fault occurs repeatedly…
Fault 161 means the burner is in a fault state due to an access fault in HBMU heat management unit data memory. The manual's first action is: “Reset the appliance. If the fault occurs repeatedly, replace the HBMU heat…
Fault 160 indicates the burner is in a fault state due to a communication error on the CAN bus. The manual's first action is: “Check connection to CAN bus subscribers (INR, HBMU). Check connections to external CAN bus…
Fault 142 means the burner is in a fault state due to communication restriction on CAN bus involving INR. The manual's first action is: “Check the fan unit for correct function. For this, check the stepper motor of th…
Fault 104 indicates a problem with the EM-EA1 extension (DIO electronics module) because an external fault message input is active. The manual's first action is: “Check connected external device.”