Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
The value of the special register for setting PWM/DPWM pulse width and period is abnormal. The manual's first action is: “• Modify the value of the special register and restart PWM.”
The channel specified by communication or built-in I/O instructions lacks appropriate parameter settings. The manual's first action is: “• Verify that the parameter setting of the channel specified by instructions usi…
An instruction that cannot be used in an interrupt routine program is being used. The manual's first action is: “• Modify the program so that no instruction whose use is disabled by the interrupt routine program is us…
Modules subsequent to the bus conversion module are using an operand that cannot be used. The manual's first action is: “• Modify the program so that no operand whose use is disabled for modules subsequent to the bus …
An instruction that cannot be used in an interrupt routine program is being used. The manual's first action is: “• Modify the program so that no instruction whose use is disabled by the interrupt routine program is us…
Auto tuning time is longer than necessary due to insufficient range or filter settings. The manual's first action is: “• Increase the difference (ULV - LLV) between the upper limit and lower limit of the output value …
Auto tuning time is longer than necessary due to insufficient range or filter settings. The manual's first action is: “• Increase the difference (ULV - LLV) between the upper limit and lower limit of the output value …
The variation of the measured value is too small compared with the output value during auto tuning. The manual's first action is: “• Multiply the measured value (PV) by "10" so that the variation of the measured value…
The I/O numbers of the reserved module specified in the I/O assignment setting overlap those of other modules. The manual's first action is: “Make sure that the parameters are consistent with the connections.”
Parameters for a standard input/output module are set to a high-speed pulse input/output module. The manual's first action is: “Make sure that the parameters are consistent with the connections.”
The module specified in the I/O assignment setting is not connected. The manual's first action is: “Make sure that the parameters are consistent with the connections.”
No available parameters exist for the connected module, indicating a mismatch or missing configuration. The manual's first action is: “Make sure that the parameters are consistent with the connections.”
The module position specified in parameters differs from that physically connected. The manual's first action is: “Make sure that the parameters are consistent with the connections.”
The number of I/O points specified in parameters does not match those connected to the module. The manual's first action is: “Make sure that the parameters are consistent with the connections.”
An error occurred while writing during RUN mode; set CPU to STOP and re-write project data. The manual's first action is: “Set the CPU module to STOP and write a set of project data.”