Omron OMNUC G Error 45: Absolute multi‑turn counter fault

Omron OMNUC G · taken from the manufacturer’s manual, pages cited

Fault code45

Absolute multi‑turn counter fault is detected when there is an abnormal multi‑turn counter or AB phase signal, indicating an encoder fault. The manual's first action is: “• Replace the servo motor.”

Model
Omron OMNUC G
Display shows
Absolute multi‑turn counter fault (45)
Type
Fault code
Source
Manual p. 343

What 45 means

Absolute multi‑turn counter fault p. 408

Common causes

  • Detected abnormal multi‑turn counter or AB phase signal. p. 408
  • Encoder fault. p. 408

What to do

  1. • Replace the servo motor. p. 408

Before you service the product, read the safety instructions in the manual p. 273.

If 45 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.

This page summarises what the manufacturer’s manual says about 45; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.