Over Regeneration Alarm is triggered when the regeneration power exceeds the allowable limit or reaches 95% of it. The manual's first action is: “Reduce the set value.”
- Model
- Mitsubishi MR‑E‑AG
- Display shows
- Over Regeneration Alarm (AL.98)
- Type
- Alarm code
- Source
- Manual p. 82
What AL.98 means
Over Regeneration Alarm p. 82
Common causes
- The regeneration power may exceed the allowable regeneration power of the built-in regeneration resistor or the regeneration braking component. p. 82
- Regeneration power reaches 95 % of the allowable regeneration power of the built-in regeneration resistor or regeneration braking component. p. 82
- 1. Reduce the set value. p. 82
- 2. Replace with a regeneration braking component of higher power rating. p. 82
- 3. Decrease the load. p. 82
What to do
- Reduce the set value. p. 82
- Replace with a regeneration braking component of higher power rating. p. 82
- Decrease the load. p. 82
Before you service the product, read the safety instructions in the manual p. 4.
If AL.98 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Mitsubishi service.
This page summarises what the manufacturer’s manual says about AL.98; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi. Found a mistake? Report an error.