Mitsubishi MR‑E‑AG Error AL.8A: Serial Communication Timeout Fault

Servo amplifier · taken from the manufacturer’s manual, pages cited

Fault codeAL.8A

Serial Communication Timeout Fault happens when the communication cable is open, the communication cycle is too long, or there is a protocol error. The manual's first action is: “Repair or replace the communication cable.”

Model
Mitsubishi MR‑E‑AG
Display shows
Serial Communication Timeout Fault (AL.8A)
Type
Fault code
Source
Manual p. 81

What AL.8A means

Serial Communication Timeout Fault p. 81

Common causes

  • Communication cable open circuit. p. 81
  • Long communication cycle caused by setting of parameter 36. p. 81
  • Communication protocol error. p. 81

What to do

  1. Repair or replace the communication cable. p. 81
  2. Set the parameter correctly. p. 81
  3. Modify the communication protocol. p. 81

Before you service the product, read the safety instructions in the manual p. 4.

If AL.8A is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Mitsubishi service.

This page summarises what the manufacturer’s manual says about AL.8A; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi. Found a mistake? Report an error.