Mitsubishi MR‑E‑AG Error AL.46: Servo Motor Overheat

Servo amplifier · taken from the manufacturer’s manual, pages cited

Error codeAL.46

The Servo Motor Overheat code indicates the ambient temperature of the servo motor exceeds 40 °C, the servo motor is in overload condition, or the encoder's thermal protection device has failed. The manual's first action is: “Reassess the environment to ensure ambient temperature is between 0 °C and 40 °C.”

Model
Mitsubishi MR‑E‑AG
Display shows
Servo Motor Overheat (AL.46)
Type
Error code
Source
Manual p. 80

What AL.46 means

Servo Motor Overheat p. 80

Common causes

  • Ambient temperature of the servo motor exceeds 40 °C. p. 80
  • Servo motor is in overload condition. p. 80
  • Encoder's thermal protection device has failed. p. 80

What to do

  1. Reassess the environment to ensure ambient temperature is between 0 °C and 40 °C. p. 80
  2. Reduce the load. p. 80
  3. Replace the servo motor. p. 80

Before you service the product, read the safety instructions in the manual p. 4.

If AL.46 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Mitsubishi service.

This page summarises what the manufacturer’s manual says about AL.46; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Mitsubishi. Found a mistake? Report an error.